Equipment summary:
ozone is a major factor in rubber cracking although it is rare in the atmosphere, ozone aging Machine simulates and enhance the condition of ozone in the atmosphere to study the effects of ozone on rubber, and then identify and evaluate the method to resist ozone and aging for rubber, adopt effective anti-aging measures to enhance the life of rubber products.
Corresponding standard:
JIS K 6259 ASTM1149 ASTM1171 ISO1431 DIN53509 GB7762 GB/T13642
Applicable industries:
Simulated Environmental Rubber Plastic Ozone Aging Test Machine is widely used to control products quality in measuring quality control; Rubber & Plastics; automobile production; wire and cable; packing materials; instruments and meters; medical equipment; civilian nuclear energy; civil aviation; colleges and universities; research laboratories; inspection arbitration, and technical supervision departments and other rubber products.
Techincal parameter:
Model |
ZT-4015 |
Ozone concentration |
5~300pphm,adjustable 100~1000pphm,adjustable (two range choose one) |
Temperature |
RT+10~+70℃ |
Ozone produced mode |
Ozone generator or UV absorption method |
Inside air velocity |
over 2 feet/sec |
Degree of ozone concentration fluctuation |
10% |
Inside size |
500×500×600mm |
Air flow |
A.0-6 cfm;B. 10-20 cfh |
Weight |
250kg |
Power |
AC220V,15A |
Accessories |
tensile fixture 6 groups |
Main function:
Simulated Environmental Rubber Plastic Ozone Aging Test Machine is used to test the ozone environment, the characteristics of crack-resistant rubber, ozone resistance testing machine, can control and adjust the concentration of ozone environment, to determine the anti-ozone properties of the specimen.
Main feature:
Equipment by the occurrence of silent and efficient ozone generator ozone gas, and a certain amount of air processed, the switch in the mixture into the chamber, the continuous line UV detector to detect the concentration of ozone, ozone generator control feedback to the systems to control system settings according to the occurrence of effective control of ozone to the ozone chamber to maintain the appropriate concentration of work by heating humidification systems to meet all the test conditions.