Main usage:
1. Measure the total sulfur mass percentage content of crude oil, petroleum, heavy oil, diesel oil, kerosene, gasoline, naphtha;
2. Measuring the total sulfur content of coal chemical products, such as primary benzene;
3. Measurement of total sulfur or sulfide content in other liquid samples;
4. Determination of carbon, total sulfur or SO3 content in fine powder samples, such as petroleum coke modified asphalt.
Product configuration:
Sulfur measurement range |
0.0017% ~ 5% |
Repeatability (r) |
< 0.02894(X+0.1691) |
Reproducibility (R) |
< 0.1215(X+0.05555) |
Detection limit |
10ppm |
Oil quantity |
5ml(equivalent oil layer thickness 4mm) |
Measurement time |
60, 120, 240, 300, 600 seconds, any setting |
Measurement times |
2, 3, 5, 10, 50 arbitrary Settings, the end of the measurement to give the average and standard deviation |
Number of correction curves |
a total of 9 working curves,5 for one straight line,4 for binomial parabola |
Working conditions |
temperature 5 ~ 40℃ |
Relative humidity |
≤ 85%(30℃) |
Power supply |
AC220V±20V,50Hz |
Rated power |
30W |
Size |
468mm×368mm×136mm |
Weight |
13kg |
Instrument characteristics:
1. Mechanical and electrical integrated microcomputer design, simple and beautiful;
2. Wide detection variety, wide detection range, fast analysis speed, less standard sample consumption;
3. Using fluorescence intensity ratio comparative analysis method, temperature, atmospheric pressure, C/H ratio (C/H) automatic correction;
4. Large screen LCD display, operation man-machine dialogue; Operation error, can sound automatic alarm;
5. Automatic diagnosis function, through counting measurement and energy spectrum measurement, judge the working state and electrical parameters of the instrument;
6. The instrument has a standard serial communication RS-232C interface, which can be connected to a computer or computer networking system;
7. Use disposable single-sided Mylar film sample cup to avoid cross contamination; The sample cup is made of multifunctional pressing parts, which is fast and convenient. There are holes on the lid of the cup and the sample number, S%(m/m) and date can be recorded.
8. The single sample table is placed on the guide rail slider, and the positioning is very accurate;
9. Large storage capacity of instrument data, content analysis results and calibration curve parameters can be checked at any time;
10. The use of thermal printer, the replacement of printing paper is very convenient, but also saves the printing ribbon consumables;
11. Safe X-ray protection measures, no harm to individuals and groups of X-ray ionizing radiation.