VST Vicat Softening Point Tester , HDT Tester
Description:
Thermal deformation Vicat and softening point temperature measuring instrument uses PLC programmable controller for temperature adjustment and computer display operation. The product is simple to operate, convenient to use, stable in performance, and high in accuracy. The test temperature and deformation can be monitored in real time during the test. At the end of the test, the system automatically stops heating and can print test reports and test curves. This series of models is an indispensable instrument for self-inspection by quality inspection units, colleges and universities.
Standard:
IS075-2013 "Determination of Plastic Load Deformation Temperature"
ASTM D 648 "Test method for thermal deformation temperature of plastics"
ASTM D 1525 "Test Method for Softening Temperature of Plastic Vicat"
Technical Parameters:
Temperature control range |
ambient temperature—300 ℃ |
Heating rate |
(120 ± 10) ℃ / h (12 ± 1) ℃ / 6min ;(50 ± 5) ℃ / h (5 ± 0.5) ℃ / 6min |
Temperature indication error |
0.1 ℃ |
Temperature control accuracy |
± 0.5 ℃ |
Maximum deformation error |
± 0.001mm |
Deformation measurement range |
0-10mm |
Number of sample holders |
3 |
Mass of load bar and pallet |
68g |
Test span range |
64mm or 100mm (according to standard) |
Fuel tank capacity |
about 25L |
Heating medium |
methyl silicone oil or transformer oil |
Cooling method |
water cooling or natural cooling below 150 |
Heating power |
4kw |
Advantage:
1.Intelligent PID adjustment, accurate heating rate, accurate temperature control and no difference.
2.Can perform thermal deformation test of various standard splines.
3.Vica softening point test for various standard splines.
4.Can simultaneously perform thermal deformation and Vicat softening point test.
5.Automatically calculate required load according to test standards and spline size.
6.Two kinds of heating rate can be selected, free switching, simple operation.
7.Support a variety of tests, color separation processing of test curves, and intuitively see the test process of each group of samples.
8.After the test is completed or exceeds the upper temperature limit, the temperature control is turned off and shut down by itself.
9.Double protection with software over-temperature protection and external mechanical over-temperature protection, so there is no worries about testing.
10.Various report settings and perfect report printing function
Computer |
1 set |
||
Printer |
1 set |
||
Sample racks |
3 piece |
||
Hot deformation head |
3 Piece |
||
Vika needles |
3 Piece |
||
Multi-purpose power socket |
1 set |
||
Weights |
3 sets ( check below specification) |
||
1000g |
12 Piece |
932 |
3 Piece |
500g |
3 Piece |
200g |
6 Piece |
100g |
3 Piece |
50g |
3 Piece |
20g |
6 Piece |
10g |
6 Piece |
5g |
3 Piece |
2g |
3 Piece |
1g |
3 Piece |
|
|