Compliance standard:
1510 Rotational Viscometer (High Temperature Viscometer) adopts a coaxial center structure and uses a small amount of sample adapter. The amount of sample required for each measurement is very small, and the temperature is controlled quickly and accurately. The full scale and the linearity of each block are all calibrated through the PC interface and calibrated with standard samples of different viscosities to ensure that the instrument has high accuracy and repeatability. It has a wide measurement range and is suitable for testing low and medium viscosity samples such as polyethylene wax, hot melt adhesive, rosin, and asphalt.of measurements suitable for testing of different materials.
Technical parameters:
Model |
1510 Portable High Temperature Viscometer |
Measuring range |
3-1600000mPa.s |
Dishplay |
Backlit LCD, digital display |
Speed(r/min) |
0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 |
Rotor |
18#, 25#, 31#, 34# (choose 1 from 4) |
Measuring range(mPa.s) |
Rotor #18: 3 – 10,000; sample volume 7ml Rotor #25: 480 – 1.6 M; sample volume 9ml Rotor #31: 30 – 100,000; sample volume 10.5ml Rotor #34: 60 – 200,000; sample volume 11ml |
K = 1,000; M=1,000,000 |
|
Test error |
±2% (Newtonian liquid) |
Repetitive error |
±1%(Newtonian liquid) |
Temperature control range |
Room temperature plus 10℃-250℃ (300℃ optional) |
Temperature control accuracy |
0.1℃ |
Dimension |
300 × 300 × 450mm |
Weight |
12kg |
Main features:
1. The horizontal bubble is placed in front, and you can sit and adjust the level, which is very convenient.
2. With timing measurement function. Most of the samples we measure are typical non-Newtonian liquids, and their viscosity is not only related to temperature and shear rate, but also to the length of measurement time. In order for the measured data to be comparable, the time of measurement must be consistent.
3. The display precision of measurement data is two decimal places.
4. The measurement data is directly displayed on the LCD screen without secondary calculation;
5. Using a small sample adapter, the amount of sample required for the test is very small, usually only 7-12ml;
6. Temperature control range: room temperature plus 10°C - 250°C (optional 300°C heating furnace)
7. The viscometer is equipped with an RS232 interface, which can be directly connected to a micro-printerr.
Our company also has a number of stepless speed control touch screen high temperature viscometer (right image), the maximum range of 80 million, optional data software, showing shear rate and viscosity rheological curve