en English ru Russian

News

News

Contact Us

You are here:Home >> News >> Zotai News

Zotai News

The difference between rubber vulcanizer and Mooney viscometer

Time:2024-01-13 Views:118


Similarities:

1. Both instruments are used to test rubber, and their appearance looks the same.

 

Differences:

1. Two different testing contents

2. The performance of the Mooney viscometer is used to measure the processing performance of rubber materials. Mooney viscosity is small, and the rubber material has good fluidity during processing; The Mooney viscometer can also measure the scorching time of rubber materials, which is the time to test the safe processing of rubber materials.

3. The performance of the vulcanizer is to measure the entire vulcanization characteristics of the rubber material, and the testing temperature is the same as the vulcanization temperature of the rubber material. The vulcanizer obtains a complete vulcanization curve, on which the positive vulcanization point can be seen, which is the positive vulcanization time of the rubber material obtained. High torque is related to hardness and tensile strength.

4. The test temperature of the Mooney viscometer is 100, and the scorch test temperature is 120.

5. The Mooney viscometer is a device that continuously rotates the rotor to shear the rubber material and measure the torque.

6. The rotor less vulcanization instrument is a device that swings the lower mold cavity back and forth, driving the rubber material to oscillate sine and measure the torque.

Mooney Viscometer Technical Parameter:

Control temperature range

Normal temperature~200℃

Temperature display resolution

0.01℃0.1 ℃ common type of imported temperature controller temperature

Temperature control accuracy

±0.3℃

Calibration accuracy

Mooney value ±0.5

Rotor speed

2 rotation/ min ±0.02rotation/ min

Torque range

Mooney value 0200

Torque resolution

 Mooney value 0.1

Print content

Date, time, temperature, Mooney scorch curve and MV,T5,T35,T3,T18,@15,@30

Power

50HZ, 220V±10



Laboratory Rubber Rotorless Rheometer Technical Parameters:

Model

ZT-1005 Laboratory Rubber Rotorless Rheometer

Meet standard

GB/T16584 / IS06502

Temperature tester

 Room temperature to 200°C

Heating speed

room temperature—200℃,about 10 min

Temperature accuracy

≤ ±0.1°C

Temperature resolution

0.1°C

Torque range

0-5N.M,0-10N.M,0-20N.M

Torque resolution

0.001NM

Motor rotating speed

100 times / min

Rotor range

Adopt 4 setting: 25, 50, 100, 200lbs per inch

Die body pendulum 

1.7Hz±0.1Hz(100r/min)

Rotor pendulum angle

±0.5°, ±1°, ±3°

Testing time setting

3min--120min,choose freely

Air compression

0.5Mpa--0.65MPa

Ambient temperature

0-35°C

Test result

Printing:date,time,temperature,vulcanization curve,temperature curve,ML,MH,ts1,ts2,t10,t50,Vc1,Vc2.

Consumption power

800 w

Dimension 

640mm×580mm×1300mm

Power

Single phase, 220V±10%, 50Hz

Display

Windows + software

Weight

About 260kg

CONTACT

    Tel: 86-769-22888875
    Ph: 8618033010616
    Wechat: 8618033010616
    What‘s app:8618576390297
Product
Rubber and Plastic Test Machine
Metal Detector
Tensile Test Equipment
Environment Test Chamber
Viscometer
Wire and Cable Tester
About Us
Zotai Profile
Zotai Certification
Zotai Customer
Zotai Service
News
Zotai News
Industry News
REQUEST QUOTE

Factory address: Building 27, XX Road, XX Street, Dongguan City Bao ‘an District, Shenzhen, Guangdong 518104, China

©2023 Dongguan Zotai Instrument Technology Co., Ltd.  

All Rights Reserved.

Web Design—Tiandixin